Edbro – Safety Equipment
Edbro – High Voltage Alert
Increase operator safety when tipping under power lines with the Edbro HVA unit
Benefits
- Clear warning to operator of potential danger in tipping
- Reduces the risk of power line contact, improving the safety of tipping
Features
- Compact detection antenna mounted within chassis cab
- In-cab warning unit with clear audio and visual warnings
- 12-24 volt unit easily fitted to a range of vehicles including tippers and cranes
| General |
| Operating voltage | 12 - 24 vDC |
| Nominal operating current | < 150 mA |
| Size | 130 mm (W) x 35 mm (H) x 25 mm (D) |
| Weight | 155 g |
| Nominal operating temperature | -5 to +55 °C |
| HV detection range | Up to 100 metres (7 meters min, adjustable) |
| Warning tone | Approx 85 db (high pitched pulsed buzzer) |
| Visual warning | High intensity red flashing LED |
| Power indicator | High intensity green LED |
| Mute facility | 30 seconds * |
| *Mute can be activated for 30 seconds then alarm sounds until muted again |
| Detection Antenna |
| Length | 235 mm |
| Weight | 60 g |
Edbro – Inclinometer
Tip with safety not with guesswork using the Edbro Inclinometer for rigid truck applications
Benefits
- Continual monitoring of tipping angle during operation to reduce risk of accident
- Increased assistance in preventing potential tipper overturns
- Optimised driver safety to reduce risk of injury and potential liability claims
Features
- Easy to read in-cab display unit
- Pneumatic tipping cut off valve
- IP rated suzi connectors/suzi cable
- Protective ABS cover
- IP68 sensor complete with state of the art 3D sensor to indicate sideways chassis movement with accuracy of 0.1° to 360°
- Options for trailer and rigid chassis
- 12 or 24 volt options available
| General |
| Operating voltage | 24 vDC |
| Nominal operating current | 400 mA |
| Measurement range
(dependent on model) | ±8 ° (standard) ±10 ° (modified) ±15 ° (off road) |
| Sensor operating temperature | -30 to +55 °C |
| Resolution | ± 0.1 ° |
| Valve operating voltage | 24 vDC |
| Valve operating current | 170 mA |
| Valve operating pressure | 0 to 125 PSI |
| Valve operating temperature | 0 to +50 °C |
| Voice Warning Sounder |
| Operating voltage | 12 - 24 vDC |
| Nominal operating current | 500 mA |
| Sound level | 85 db |
| Frequency | Speech |
| MIRA tested for on & off highway (sounder only) |
| Protection Ratings |
| External electronic connections | IP68 |
| Sensor casing Aluminium | IP68 |
| Sensor shield | ABS IP68 |